Conference Publications

  1. The Role of Heterogeneity Analysis for Differential Diagnosis in Diffusion-Weighted Images of Meningioma Brain Tumors”, M Safari, A Fathi Kazerooni, M Babaie, M Nabil, M Rostami, P Ghavami, M Saneie Taheri, H Saligheh Rad, 24th ISMRM Scientific Meeting 2016, Singapore.
  2. Can Diffusion Weighted MRI Assess Early Response of Lymphadenopathy to Induction Chemotherapy in Nasopharyngeal Cancer: A Heterogeneity Analysis Approach”, M Beigi, A Fathi Kazerooni, M Safari, M Alamolhoda, A Ameri, S Moghdam, M Shojaee Moghadam, H Saligheh Rad, 24th ISMRM Scientific Meeting 2016, Singapore.
  3. Distributed Compressed Sensing to Accelerate Cine Cardiac MRI”, J Zamani, H Saligheh Rad, A Nasiraei Moghaddam, the SCMR/Euro CMR Joint Scientific Sessions, February 5-7, 2015, Nice, France.
  4. Generation of MR-based Attenuation Correction Map of PET Images in the Brain Employing Joint Segmentation of Skull and Soft Tissue from Single Short-TE MR Imaging Modality”,A Fathi Kazerooni, MH A’arabi, and H Saligheh Rad, MICCAI 2014 Workshop on Computational Methods for Molecular Imaging (CMMI’14), September 14, 2014, Massachusetts Institute of Technology (MIT) in Cambridge Mass., USA.
  5.  “A New Approach for Visualization of Dynamic PET Images Employing Diffusion-Map Space”, MH A’arabi, S Adebileje, M Shandiz, and H Saligheh Rad, MICCAI 2014 Workshop on Computational Methods for Molecular Imaging (CMMI’14), September 14, 2014, Massachusetts Institute of Technology (MIT) in Cambridge Mass., USA.
  6. A Novel Approach for Baseline Correction in 1H-MRS Signals Based on Ensemble Empirical Mode Decomposition”, MA Parto Dezfouli, M Parto Dezfouli, and H Saligheh Rad, 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC’14), August 26-30, 2014, Chicago, Illinois, USA.
  7. A High Throughput and Efficient Visualization Method for Diffusion Tensor Imaging of Human Brain Employing Diffusion-Map Space “, MH A’arabi, A Fathi Kazerooni, N Salehi, and H Saligheh Rad, 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC’14), August 26-30, 2014, Chicago, Illinois, USA.
  8. A Fully Automated and Reproducible Level-set Segmentation Approach for Generation of MR-based Attenuation Correction Map of PET Images in the Brain Employing Single STE-MR Imaging Modality“, A Fathi Kazerooni, MH Aarabi, M R Ay, H Saligheh Rad, 3rd Conference on PET/MR and SPECT/MR (PSMR2014).
  9.  “A Robust MR-Based Attenuation Map Generation in Short-TE MR Images of the Head Employing Hybrid Spatial Fuzzy C-Means Clustering and Intensity Inhomogeneity Correction“, MH Aarabi, A Fathi Kazerooni, P Khateri, M R Ay and H Saligheh Rad , 3rd Conference on PET/MR and SPECT/MR (PSMR2014).
  10.  “A hybrid method for generation of attenuation map for MR-based attenuation correction of PET data in prostate PET/MR imaging”, M Shirin Shandiz, MH Aarabi, P Ghafarian, M Bakhshayesh Karam, H Saligheh Rad and M R Ay, 3rd Conference on PET/MR and SPECT/MR (PSMR2014).
  11. Wavelet Graphs on Mutual Information Functional Connectivity for MS Patients in Resting State fMRI”, E Eqlimi, A Eshaghi, N Riyahi Alam, A Ahmadian, M A Sahraian and H Saligheh Rad, 20th Annual Meeting of the Organization for Human Brain Mapping (OHBM 2014)
  12. Automatic Bone Segmentation in Pelvis Area with Bone Marrow Metastases Employing Local Level-Set with Prior information; Applications in Breast Cancer Treatment Monitoring and Surgical Planning”, F Sanaei Nezhad, H Soltanian-Zadeh, H Saligheh Rad, 28th International Congress and Exhibition on Computer Assisted Radiology and Surgery (CARS2014), 2014
  13. Multi-parametric (ADC/PWI/T2-W) Image Fusion Approach for Accurate Semi-Automatic Segmentation of Tumorous Regions in Glioblastoma Multiforme”, A Fathi Kazerooni, M Mohseni, H Saligheh Rad, 28th International Congress and Exhibition on Computer Assisted Radiology and Surgery (CARS2014), 2014.
  14. Diffusion-Map: A Novel Visualizing Biomarker for Diffusion Tensor Imaging of Human Brain White Matter”,M H A’arabi, A Fathi Kazerooni and Hamidreza Saligheh Rad, MICCAI 2014 Workshop on Computational Diffusion MRI (CDMRI14).
  15. Investigation of Relationship between Free-Water T1 and Age in Human Cortical Bone Employing Short-TE 1H-MRI at 1.5T”, A Akbari, S Abbasi Rad, M Shojaee-Moghaddam and H Saligheh Rad, Proceedings of 22nd ISMRM Scientific Meeting and Exhibition, 2014, Milan, Italy.
  16. Mutual Information Weighted Graphs for Resting State Functional Connectivity in fMRI Data”, E Eqlimi, N Riyahi Alam, MA Sahraian, A Eshaghi and H Salighe Rad, Proceedings of 22nd ISMRM Scientific Meeting and Exhibition, 2014, Milan, Italy.
  17. Segmentation of Bone From ADC-Maps in Pelvis Area Using Local Level-set and Prior Information”, F. Sanaei Nezhad, H. Saligheh Rad, H. Soltanian-Zadeh, IEEE International Symposium on Biomedical Imaging (ISBI), 2014.
  18. Accurate Segmentation of Tumorous Regions in High-Grade Glioma Employing a Multi-parametric (ADC/PWI/T2W) Image Fusion Approach”,A Fathi Kazerooni, M Mohseni, H Saligheh Rad, ESMRMB 2013, Tolouse/FR.
  19. A Novel Non‐Rigid Registration Approach for Accurate Quantification of Dynamic Contrast Enhanced MR Imaging (DCEMRI) in Ovary Employing Residual Complexity Framework”, A Fathi Kazerooni, L Torbati, M Malek, and H Saligheh Rad, Proceedings of 21st ISMRM Scientific Meeting and Exhibition, 2013, Salt Lake City, Utah, USA.
  20. Smoothly Clipped Absolute Deviation (SCAD) Regularization for Compressed Sensing MRI Using an Augmented Lagrangian Scheme”, A Mehranian, H Saligheh Rad, MR Ay, A Rahmim, H Zaidi, IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), 2012, pp. 3646-3653.
  21. A Wavelet- Based Similarity Measure to Register Pre-/Intra-Operative MR Images of the Brain”, A Fathi Kazerooni, A Ahmadian, H Saberi, V Asayesh and H Saligheh Rad, The 2012 International Conference on Image Processing, Computer Vision, and Pattern Recognition (IPCV’2012)”, Las Vegas, Nevada.
  22. Generation of Attenuation Map for MR‐Based Attenuation Correction of PET Data in the Head Area Employing 3D Short Echo‐Time MR Imaging”, P Khateri, H Saligheh Rad, A Fathi Kazerooni, M Ay, The first PET/MR and SPECT/MR conference on New Paradigms for Combined Modalities in Molecular Imaging Conference, 2012, Elba Island, Italy.
  23. Application of Split Bregman Optimization Method for Compressed Sensing CE-MRA”, J Zamani, H Saligheh Rad, and A Nasiraei Moghaddam, Proceedings of IEEE Engineering in Medicine and Biology (EMBC’12), August 2012, San Diego, USA.
  24. An Efficient Algorithm for Registration of Pre- and Intra- Operative Brain MRI Images to Correct Intensity Inhomogeneity”, A Fathi Kazerooni, A Ahmadian, H Saberi, J Alirezaie and H Saligheh Rad, Proceedings of the 11th International Conference on Information Sciences, Signal Processing and their Applications (ISSPA’12), July 2012, Montreal, Canada.
  25. 3D TV-Based Compressed MR Image Reconstruction Using a Primal Dual Algorithm,” A Mehranian, H Saligheh Rad, M Ay and A Rahmim, Proceedings of 20th ISMRM Scientific Meeting and Exhibition, Melbourne, Australia.
  26. Segmentation of Brain Tumors in MRI Images Using Multi-scale Gradient Vector Flow”, A Fathi Kazerooni, A Ahmadian, N Dadashi Serej, H Saligheh Rad, H Saberi, H Yousefi and P Farnia, Proceedings of 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC’11), September 2011, Boston, USA.
  27. Feasibility of in vivo phosphorus imaging of cortical bone at 7T in humans” , P-H Tsai, AC Seifert, AC Wright, H Saligheh Rad, JF Magland, HK Song, MB Leonard and FW Wehrli, Proceedings of 19th ISMRM Scientific Meeting and Exhibition, April 2011, Montreal, Canada.
  28. Bone Water Concentration as a New Metric for Cortical Bone Quality” , H Saligheh Rad, J Love, JF Magland, M Leonard and FW Wehrli, oral presentation, Proceedings of 18th ISMRM Scientific Meeting and Exhibition, April 2010, Stockholm, Sweden.
  29. Correcting for Gradient Imperfections in Ultra- Short Echo Time Imaging”, JF Magland, H Saligheh Rad and FW Wehrli, Proceedings of 18th ISMRM Scientific Meeting and Exhibition, April 2010, Stockholm, Sweden. 
  30. A Novel Full-Three-Dimensional MIMO Mobile-to-Mobile Channel Reference Model” , GR Bakhshi, K Shahtalebi and H Saligheh Rad, Proceeding of 3rd International Conference on Signal Processing and Communication Systems (ICSPCS’2009), Nebraska, USA, September 2009.
  31. High Precision Translational Motion Correction for Micro-MRI of Trabecular Bone Using Cartesian Navigators”, H Saligheh Rad, MJ Wald, JF Magland and FW Wehrli, oral presentation, Proceedings of 17th ISMRM Scientific Meeting and Exhibition, April 2009, Hawaii.
  32. Evaluation of Motion Corruption on Image Quality in Micro MRI of Trabecular Bone: Impact on Structural Parameters” ,YA Bhagat, MJ Wald, CS Rajapakse, H Saligheh Rad, JF Magland, MB Leonard and FW Wehrli, poster presentation, Proceedings of 17th ISMRM Scientific Meeting and Exhibition, April 2009, Hawaii.
  33. On the efficiency of directional antennas in MIMO communication systems”, O Darvishi, B Abolhassani, H Saligheh Rad, IEEE Sarnoff Symposium, 2009. SARNOFF’09, pp. 1-5.
  34. Characterization of the impact of power normalization on the MIMO mutual information” , O Darvishi, B Abolhassani and H Saligheh Rad, Proceedings of 4th International Symposium on Telecommunications, August 2008, Tehran, Iran.
  35. Low SNR Regime Capacity Analysis of MIMO Systems Using Directional Antennas”, P Shariatpanahi, AA Shishegar, BH Khalaj and H Saligheh Rad, Proceedings of International Symposium on Telecommunications 2008 (IST’08), Tehran, August 2008.
  36. Impact of Physical Channel Properties on the Capacity of MIMO Communication Systems”, O Darvishi, B Abolhassani and H Saligheh Rad, Proceedings of 16th Iranian Conference on Electrical Engineering (ICEE’08), May 2008, Tehran, Iran.
  37. Blind Multiuser Data Estimation in Asynchronous and Unequal Power DS-SS Systems without any Prior Knowledge of Spreading Sequences”, S Ghavami, H Alikhanian , B Abolhassani and H Saligheh Rad, Proceedings of 2009 IEEE Sarnoff Symposium, Princeton, New Jersey.
  38. Interference Cancellation in Coherent CDMA Systems Using Parallel Iterative Algorithms”,  K Shahtalebi, GR Bakhshi and H Saligheh Rad, Proceedings of International Symposium on Telecommunications 2008 (IST’08), Tehran, August 2008.
  39. Decorrelating Closely-Placed Antennas by Pattern Design in Uniform Scattering Environments”, P Shariatpanahi, BH Khalaj, AA Shishegar and H Saligheh Rad, International Conference on Advanced Communication Technology 2008 (ICACT’08), Korea, Feb 2008.
  40. Non-Fixed Scatterers and Their Effects on MIMO Multicarrier Fading Communication Channels”, H Saligheh Rad, S Gazor and P Shariatpanahi, IEEE Global Communications Conference 2007 (GLOBECOM’07), July 2007.
  41. Space-Time-Frequency Characterization of 3D Non-Isotropic MIMO Multicarrier Propagation Channels Employing Directional Antennas”, H Saligheh Rad and S Gazor, IEEE Wireless Communications and Networking Conference 2007 (WCNC’07), March 2007.
  42. A Fast and Universal Neuro-Based SVM Algorithm for Multi-Level Converters” , M Saeedifard, H Saligheh Rad, A Bakhshai and R Iravani, IEEE APEC’07.
  43. A Cross-Correlation Model for Non-Isotropic Scattering with Non-Omnidirectional Antennas in MIMO Propagation Channels” , H Saligheh Rad and S Gazor, 6th IEEE Workshop on Signal Processing Advances in Wireless Communications 2005 (SPAWC’05), pp. 251–255, June 2005.
  44. A 3D correlation model for MIMO non-isotropic scattering with arbitrary antenna arrays”, H Saligheh Rad, S Gazor, IEEE Wireless Communications and Networking Conference, 2005, (WCNC’05), pp. 938-943, vol. 2.
  45. The Effect of Mobile Station Rotation on a Correlation Model for Microcellular Environments”,  H Saligheh Rad and S Gazor, IEEE Global Telecommunications Conference, 2004 (GLOBE- COM ’04), pp. 3058–3062, vol. 5, July 2004.
  46. MIMO Space-Time Correlation Model for Microcellular Environments”,  H Saligheh Rad and S Gazor, 5th IEEE Workshop on Signal Processing Advances in Wireless Communications 2004 (SPAWC’04), pp. 125–129, Lisbon, Portugal, July 11-14, 2004.
  47. Matrix Form Lapped Space Time Block Coding in Frequency Selective Channels”, J Wu, H Saligheh Rad, SD Blostein and S Gazor, 22nd Biennial Symposium on Communications, Department of Electrical and Computer Engineering, Queen’s University, Kingston, May 31 – June 3, 2004.
  48. Time-Varying Coding for Space-Time Ambiguities”,  S Gazor and H Saligheh Rad, Proceedings of IEEE International Conference on Acoustics, Speech, and Signal Processing, (ICASSP’04), Montreal, May 2004.
  49. Spatial-temporal-frequency decomposition for 3D MIMO microcellular environments”, H Saligheh Rad, S Gazor, K Shahtalebi, Canadian Conference on Electrical and Computer Engineering 2004 (CCECE’04), Vol. 3, pp. 1229-1232, Niagara Falls, May 2004.
  50. WMPLS Throughput Efficiency in Multi- path Rayleigh Fading Environments” , NA Ali, H Saligheh Rad, S Gazor and H Mouftah, Canadian Conference on Electrical and Computer Engineering 2004 (CCECE’04), Niagara Falls, May 2004.
  51. An Optimal Receiver for Transmission Diversity Over Uncertain Channels”, H Saligheh Rad and S Gazor, Proceedings of IEEE International Conference on Acoustics, Speech, and Signal Processing, (ICASSP’03), vol. 4, pp. IV: 341-344, Hong Kong, April 6–10, 2003.
  52. Transmission Diversity Ambiguities and Adaptive Channel Tracking”, H Saligheh Rad and S Gazor, Proceedings of Seventh International Symposium on Signal Processing and Its Applications, (ISSPA’03), 2003, vol. 1, pp. 45–48, July 1-4, 2003.
  53. Joint Estimation and Detection for Transmit Diversity Over Fast Fading Channels” S Gazor and H Saligheh Rad, Proceedings of Seventh International Symposium on Signal Processing and its Applications, (ISSPA’03), 2003, vol. 1, pp. 37–40, July 1-4, 2003.
  54. Space Vector Modulation Based on Classification Method in Three-Phase Multi-Level Voltage Source Inverters”, A Bakhshai and H Saligheh Rad, IEEE Industry Applications Conference, Thirty-Sixth IAS Annual Meeting, vol. 1, pp. 597–602, 30 Sept.-4 Oct. 2001.
Scroll to Top